Dimensional measurement calibration of dial calipers based on JIS B 7507: 2016 standard in the measurement laboratory

Authors

  • Agnes Br Manurung Politeknik Negeri Medan, Indonesia
  • Adi Syahputra Purba Politeknik Negeri Medan, Indonesia
  • Ari Angga Manalu Politeknik Negeri Medan, Indonesia
  • Erna Juwita Politeknik Negeri Medan, Indonesia
  • Adhe Aryswan Politeknik Negeri Medan, Indonesia

DOI:

https://doi.org/10.35335/computational.v14i1.265

Keywords:

Accuracy, Calibration, Dial Calliper, Measurement, Standard

Abstract

Dial calipers are very frequently used by both measurement laboratories and production. Dial calipers need to be calibrated every 12 months. The purpose of this study is to provide an understanding of how to calibrate a dial caliper, using a method based on JIS B 7507:2016 Standard. The JIS standard itself provides guidance and reference for dial caliper calibration. Based on the calibration results obtained, it is known that the dial caliper has deviation or error values in each measurement (outside, inside, depth, and step) with values of 0.0200 mm and -0.01000, referring to an accuracy of +/-0.03mm. After evaluation based on the standard, these error values still meet the requirements of JIS B 7507-2016. The benefit of this calibration is dial calipers are important to calibrate both before and after use to ensure optimal accuracy and consistent measurement results and also this calibration performed is sufficiently valid and reliable.

References

Alsoufi, M. S., Bawazeer, S. A., Alhazmi, M. W., Hijji, H. H., Alhazmi, H., & Alqurashi, H. F. (2025). Dimensional Accuracy and Measurement Variability in CNC-Turned Parts Using Digital Vernier Calipers and Coordinate Measuring Machines Across Five Materials. Materials, 18(12). https://doi.org/10.3390/ma18122728

Amani, & Arief, D. (2013). KALIBRASI JANGKA SORONG NONIUS (VERNIER CALLIPER) BERDASARKAN STANDAR JIS B 7507 DI LABORATORIUM PENGUKURAN TEKNIK MESIN UNIVERSITAS RIAU. Australian Orthodontic Journal, 29(2), 159–163. https://doi.org/10.2478/aoj-2013-0018

Arief, D., Pahlevi, A., & Permana, A. (2021). Calibration of Dial Indicator Using Calibration Tester with JIS B 7503 Standard. The Journal of Ocean, Mechanical and Aerospace -Science and Engineering- (JOMAse), 65(2), 82–87. https://doi.org/10.36842/jomase.v65i2.204

Chen, W. M., Wang, H. X., Wang, G. W., & Liang, W. H. (2022). MACHINE VISION BASED VERNIER CALIPER READING TECHNOLOGY RESEARCH. Metrology and Measurement Systems, 29(4), 779–793. https://doi.org/10.24425/mms.2022.143070

Chusni, M. M. (2019). Handout Perkuliahan Pengenalan Alat Ukur. Handout Perkuliahan, 1, 4–16.

Fatiatun, Naja, F., Septyana, A., & Rakhmadhani, A. (2022). Pengembangan Large Size Vernier Caliper Untuk Pengukuran Benda Dalam Kehidupan Sehari-Hari. Jurnal Al-Qalam, 23(1), 47–52.

Hilal Yayan, E., Professor, A., & Zengin, M. (2020). A Key Point in Medical Measurements: Device Calibration and Knowledge Level of Healthcare Professionals. In International Journal of Caring Sciences (Vol. 13). www.internationaljournalofcaringsciences.org

Husnah, M., Nurlisa, S., Fazira, N. A., & Lubis, R. Y. (2023). Kalibrasi Jangka Sorong Digital (Vernier Calliper) Dengan Caliper Cheker Dan Gauge Block Berdasarkan Standar JIS B.7507:2016. Navigation Physic : Journal of Physics Education, 4(5), 104–112.

Irawan, A. (2019). Kalibrasi Spektrofotometer Sebagai Penjaminan Mutu Hasil Pengukuran dalam Kegiatan Penelitian dan Pengujian. Indonesian Journal of Laboratory, 1(2), 1. https://doi.org/10.22146/ijl.v1i2.44750

Ismaini, Naomi Tosani, dan N. N. H. (2021). TATAKELOLA PERAWATAN DAN UJI KALIBRASI NERACA ANALITIK DI LABORATORIUM FAKULTAS PERTANIAN UNIVERSITAS SRIWIJAYA. 1–6.

JIS B 7507, 2016: Vernier, Dial and Digital Callipers.

Kankar, P. K., Moona, G., & Desai, K. A. (2022). Measurement and Metrology in Advanced Manufacturing Processes. In Mapan - Journal of Metrology Society of India (Vol. 37, Issue 4, pp. 703–705). Springer. https://doi.org/10.1007/s12647-022-00606-w

Klebba, M., Adamczyk, A., Wąż, M., & Iwen, D. (2023). Application of Multi-Criteria Optimization Methods in the Calibration Process of Digital Measuring Instruments. Sensors, 23(6). https://doi.org/10.3390/s23062984

Lamichhane. (2024). Investigating Cost-Effective Calibration Methods for Handheld Measurement Devices: A Study on Vernier & Digital Calipers and Micrometers. Degree Program in Industrial Management, 4(2), 91.

Mila Rosa Angraini, Suprianto, S., Nur Fadilah, Yasmin Sabrina Nur Islami, & Mubayyinah Muliyadi. (2024). Analisis Keterampilan Penggunaan Alat Ukur terhadap Pemahaman Konsep pada Materi Besaran dan Satuan. DIAJAR: Jurnal Pendidikan Dan Pembelajaran, 3(2), 196–201. https://doi.org/10.54259/diajar.v3i2.2416

Mitutoyo. (2018). Accuracy and Calibration of Calipers. 1–2.

Muflikhun, M. Al., Alrifvian to, B., Mahard ika, M., & Salim, U. A. (2022). Metrologi Dalam Industri Manufaktur. Yogyakarta: Gadjah Mada University Press

Ni Luh Tirtasari. (2017). Uji Kalibrasi (Ketidakpastian Pengukuran) Neraca Analitik di Laboratorium Biologi FMIPA UNNES. 6(2), 1–13.

Nurlina, & Riska, R. (2019). Alat Ukur dan pengukuran. October, 60–63.

Rahmah, F., & Salsabila, F. F. (2022). Uji Kalibrasi Alat Ukur Massa Pada Neraca Analitik Menggunakan Metode Perbandingan Langsung. JURNAL SISFO Inspirasi Profesional Sistem Informasi, 7(2), 24–32.

Rochim, Taufiq. (2006). Spesifikasi, Metrologi & Kontrol Kualitas Geometrik 2. Bandung: ITB.

SNSU. (2020). Panduan kalibrasi Jangkal Sorong. Badan Standardisasi Nasional

Sulaeman, Cecep dan Kusnadi. 2011. Kalibrasi Temperatur Pada PT100 dan Termocouple. Jurnal Ilmiah Elite Electro Volume 2 Nomor 2 September 2011.

Xiong, J., He, W., Yuan, J., Li, M., & Ren, T. (2025). Development of calibration device for center distance caliper. Journal of Physics: Conference Series, 2954(1). https://doi.org/10.1088/1742-6596/2954/1/012036

Yoneda, H. (2022). Brief study on vernier caliper and its applications in Physics. In To Physics Journal (Vol. 9, Issue 4). http://purkh.com/index.php/tophy

Zulfebri, & Arief, D. S. (2015). Kalibrasi Jangka Sorong Jam Ukur (Dial Calliper). Journal of Chemical Information and Modeling, 15(2), 9–25.

Downloads

Published

2025-05-30

How to Cite

Manurung, A. B., Purba, A. S., Manalu, A. A., Juwita, E., & Aryswan, A. (2025). Dimensional measurement calibration of dial calipers based on JIS B 7507: 2016 standard in the measurement laboratory. International Journal of Mechanical Computational and Manufacturing Research, 14(1), 32–41. https://doi.org/10.35335/computational.v14i1.265

Most read articles by the same author(s)